Add to Cart
Vector Control AC VFD Drives with 3 Phase 380VAC for CNC Lathe
A CNC lathe is a machine tool designed to remove material from a rotating work piece, using a cutting tool. Some lathes can form hollow parts by a process called metal spinning. These parts have circular cross-sections. Metal and other materials can be turned on a lathe, including wood and plastics. CNC controlled lathes use a computer to control the process of making each part with repeated accuracy and precision.
Application Challenges
· Precise speed regulation and torque over wide speed range
· Interlock drive with operation of CNC.
· Quick acceleration even under high torque conditions
Features of V5 series matching CNC Lathe application
Features |
Benefits |
For Digital Control Machine Tool |
|
Power range of V5 VFD
Voltage: 3 phase 380VAC (323VAC – 528VAC)
Power: 1.5kw/2HP – 400kw/535HP
Specification of V5 VFD
Item |
Specification |
Input frequency |
50/60Hz |
Output frequency |
0-300Hz |
Overload current |
150% rated current 1min., 180% 10 sec., 200% 0.5 sec. |
Control mode |
sensor-less vector control, V/F control |
Starting torque |
180% 0.5Hz (180% 0.25Hz) |
Control precision |
±0.05% ( ±0.02%) |
Torque precision |
±5% |
Frequency setting mode |
Operation panel setting, terminal UP/DN setting, host computer communication setting, analog setting AI1/AI2/AI3, terminal pulse DI setting |
Efficiency |
At rated power, 7.5kW and below power class ≥93%, 45kW and below power class ≥95%, 55kW and above power class ≥98% |
Frequency setting signal |
-10V~+10V; 0~+10V; 0~20mA; 0.2Hz~50kHz |
Protection function |
Power supply undervoltage, overcurrent protection, overvoltage protection, interference protection, abnormal comparison reference input, auto-tuning failure, module protection, heatsink overtemperature protection, inverter overload protection, motor overload protection, peripheral protection, abnormal current detection, output to ground short circuit, abnormal power failure during operation, abnormal input power, output phase failure, abnormal EEPROM, abnormal relay contact, temperature sampling disconnection, encoder disconnection, abnormal +10V power supply output, abnormal analog input, motor overtemperature (PTC), abnormal communication, abnormal version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection failure, hardware overload protection |
Enclosure |
IP20 |
Cooling mode |
forced air cooling |
Vibration |
3.5mm, 2~9Hz; 10 m/s2, 9~200Hz |
Ambient temperature / Humidity |
-40 Degrees~+70 Degrees / 5~95%Rh (no condensation) |
Tips:
A variable-frequency drive (VFD) is a system for controlling the rotational speed of an alternating current (AC) electric motor by controlling the frequency of the electrical power supplied to the motor. A variable frequency drive is a specific type of adjustable-speed drive. Variable-frequency drives are also known as adjustable-frequency drives (AFD), variable-speed drives (VSD), AC drives, microdrives or inverter drives. Since the voltage is varied along with frequency, these are sometimes also called VVVF (variable voltage variable frequency) drives.